Skip to main content

05DiagnosticsDiagnostics & therapeutics

Laboratory and imaging diagnostics

Diagnostics records laboratory and imaging orders, specimens, analyser runs and results for laboratory, radiology and clinical teams.

Designed for
  • Laboratory scientists
  • Radiographers
  • Radiologists
  • Doctors who order tests
  • Ward and emergency teams
A lab scientist in a navy hijab loading a sample into an analyser
Diagnostics

Result status history

  1. 1Preliminary
  2. 2Final
  3. 3Corrected
  4. 4Amended
  5. 5Cancelled
  6. 6Entered in error
A doctor listening to a young boy's chest while his mother sits beside him

Capabilities by role

Diagnostics is the record for laboratory and imaging work, covering orders, specimens, analyser runs, results and studies.

Laboratory scientists

  • Each specimen keeps its chain of custody from collection to result.
  • Diagnostics quarantines any analyser run that fails a quality, calibration, identity, unit or interface check and withholds it from release.
  • Results carry a LOINC code for the test and a UCUM code for the unit.

Radiographers and radiologists

  • Image transfers are encrypted and resume from the point of interruption if the connection breaks.
  • Images remain in your PACS or VNA, and Diagnostics records the study.
  • Imaging exchanges use DICOMweb through the Integration Hub.

Doctors, ward and emergency teams

  • A corrected or amended result does not overwrite the previous version.
  • Each critical result creates a ward task, and the communication about it is logged as a separate event.
  • Released results are added to the patient's Fastclinic Record as signed entries.

Built-in controls

These controls are enforced by the software and apply in both deployment editions and on every plan.

Result version history

A corrected or amended result does not replace the version before it.

Quarantine of failed analyser runs

Diagnostics quarantines any analyser run that fails a quality, calibration, identity, unit or interface check and does not release it as a result.

No control of diagnostic equipment

Diagnostics records orders, runs and results. It does not control analysers or imaging equipment, and the imaging standard it uses excludes device control.

Standards supported
  • LOINC
  • UCUM
  • DICOMweb
  • HL7 v2.5.1

Frequently asked questions

For other questions, email contact@getfastclinic.com.

How are corrected laboratory results recorded?

Diagnostics records a correction as a separate version and keeps the original, overwriting neither.

What happens after the laboratory flags a result as critical?

Diagnostics records the result, and Care Operations gives the ward a task to notify, escalate, acknowledge and resolve.

Can Diagnostics connect to our analysers and PACS?

Yes, through the Integration Hub. Laboratory messages use HL7 v2.5.1 and imaging uses DICOMweb, and images remain in your PACS.

Arrange a demonstration of Diagnostics

We will demonstrate how Diagnostics would operate in your facility alongside the components it works with.